AETEK
AETEK builds PoE switches for video security installations: from compact 4-port units to 24-port switches, with PoE+ and PoE++/bt, as desktop, rack and ceiling units with daisy-chain capability, also for outdoors with fibre uplinks.
For selection, look at total PoE budget, port count, SFP uplinks and temperature range. Technical data and data sheets on every article, trade prices after login.
210 AETEK products in the catalogue – as an authorised distributor, with technical data, data sheets and trade prices after login.
Filter products
One-channel surge protector for equipment inside a building, rated to 10 Gbps: it passes 10M/100M/1G/2.5G/10G over Cat 5e or Cat 6, UTP or STP. Data and power are protected across all eight conductors, at 20 kV common mode and 4 kV differential mode, with up to 10 kA discharge current, 5 ns response and clamping of 600 V to ground and 20 V line to line. PoE support covers 802.3af, 802.3at, 802.3bt and UPoE at no more than 60 V DC, 1 A over two pairs, 2 A over four pairs and 95 W. Insertion loss is 1 dB and return loss -20 dB at 10 and 100 MHz. Nothing has to be configured, and an LED marks a spent protector. Temperature range -40 °C to 85 °C, 80 x 40 x 25 mm, 0.18 kg, two RJ45 sockets.
Not in stock · delivery 2-3 weeks
Single-channel PoE surge protector for indoor positions: next to the PoE switch, or inside a junction or power box. Data and PoE feed are covered on all eight conductors, with a 20 kV common-mode and 4 kV differential-mode level, 10 kA discharge capability, 5 ns response and clamping at 600 V to ground and 20 V between lines. It passes 10M/100M/1G/2.5G over Cat 5e or Cat 6 UTP/STP and supports 802.3af, 802.3at, 802.3bt and UPoE up to 60 V DC, with 1 A over two pairs, 2 A over four pairs and 95 W maximum. An LED shows when the protector has reached the end of its life. Working range -40 °C to 85 °C, 80 x 40 x 25 mm, 0.18 kg, two RJ45 sockets, EMC to CE, FCC, VCCI and C-Tick.
Not in stock · delivery 2-3 weeks
Single-channel surge protector for EPoC links, mounted beside the EPoC receiver to guard both the signal and the power path on the coaxial run. Two BNC sockets form the pass-through. Protection level is 6 kV in common and differential mode alike, clamping voltage 100 V in both, discharge current 2 kA at 1 kA per line, response time 5 ns. Up to 60 V DC and 1 A are permitted, at which point dissipation is 2 W. An indicator lights once the protector is used up. Wall mounted, operating and storage range -40 °C to 85 °C, humidity 5 to 95 % non-condensing, 80 x 40 x 25 mm, 0.18 kg, EMC to CE and FCC.
Not in stock · delivery 2-3 weeks
1-CH Managed PoE surge protector module for SD-504 and SD-52410KA/20KV802.3af/802.3at/802.3bt/UPoE1G/2.5G
Not in stock · delivery 2-3 weeks
Outdoor single-channel PoE surge protector rated to 10 Gbps, built into an IP67 metal enclosure with two PG16 cable entries for the RJ45 connections. All eight conductors are protected at 20 kV common mode and 4 kV differential mode, with discharge current up to 10 kA, a 5 ns response and clamping of 150 V to ground and 20 V between lines. It works with 802.3af, 802.3at, 802.3bt and UPoE at a maximum of 60 V DC, 1 A over two pairs, 2 A over four pairs and 95 W. Insertion loss 1 dB, return loss -20 dB. Operating and storage range -40 °C to 85 °C, 186.2 x 50 x 32 mm, 0.27 kg, with an LED that reports a failed protector.
Not in stock · delivery 2-3 weeks
Single-channel PoE surge protector in an IP67 metal enclosure, for wall or pole mounting out in the weather. Data and power are covered on all eight conductors: 20 kV common mode, 4 kV differential mode, discharge capability of 10 kA, 5 ns response, clamping at 150 V to ground and 20 V between lines. The link carries 10M/100M/1G/2.5G on Cat 5e or Cat 6 and supports 802.3af, 802.3at, 802.3bt and UPoE at up to 60 V DC, 1 A over two pairs, 2 A over four pairs and 95 W. An LED flags a spent protector. Operating and storage range -40 °C to 85 °C, humidity 5 to 95 % non-condensing, 186.2 x 50 x 32 mm, 0.27 kg.
Not in stock · delivery 2-3 weeks
1-Port bt PoE PD EPo2 RX Adapter1-Port EPo2 TX Adapter
Not in stock · delivery 2-3 weeks
1-Port bt PoE PD EPoC RX Adapter1-Port EPoC TX Adapter
Not in stock · delivery 2-3 weeks
1-Port bt PoE PD EPoT RX Adapter1-Port EPoT TX Adapter
Not in stock · delivery 2-3 weeks
The 2E10-110-TX-V2 is the transmitting half of an EPo2 pair and carries Ethernet and PoE together over a single two-wire line. Existing doorbell, telephone or other two-conductor wiring in the building can therefore be kept instead of being replaced — for door stations, access readers, speakers, sensors or cameras. It feeds in through one 10/100 Mbit/s RJ45 port as PSE and supplies power to IEEE 802.3af, 802.3at and 802.3bt. The unit needs no configuration, draws 2 W and comes in a metal housing for wall or optional DIN-rail mounting.
Not in stock · delivery 2-3 weeks
EPoC transmit adapter with one 75 Ω BNC port and one RJ45 PoE output that feeds as PSE under IEEE 802.3af, 802.3at and 802.3bt. It sits at the camera end of a coaxial run and powers the camera with no local supply: over RG59, RG6 or RG11 the link is rated for 9.7 W at 1,200 m with 100 Mbps, a PoE IP camera is given up to 8.3 W, and data alone travels 2,400 m. Existing coax can therefore keep serving PoE IP cameras. Power arrives either as PoE on the coax or as 56 VDC at the DC jack; the unit draws 2 W and a DIP switch turns the PoE output off. An SD-301 surge protector is available as an option. Metal case 86.6 x 47.1 x 27.0 mm, 0.2 kg, wall or optional DIN-rail mounting, operating range -20 °C to 60 °C, humidity 5 to 95 % non-condensing, EN62368-1.
Not in stock · delivery 2-3 weeks
Transmit end of an EPoT link, where data and power share one shielded Cat5e/6 STP/FTP cable wired on four pairs, two pairs or a single pair. It carries one EPoT port on RJ45 and one RJ45 PoE output acting as PSE for IEEE 802.3af, 802.3at and 802.3bt; the link is rated for 16 W at 1,200 m with 100 Mbps, at that length a PoE IP camera is given up to 9.7 W, and data alone travels 2,400 m. No intermediate switch or power supply is needed along the run. Power comes in over EPoT at 50 to 56 VDC or through the DC jack at 56 VDC, the unit itself draws 2 W, and a DIP switch turns the PoE output off. Peer-to-peer, daisy-chain and failover ring topologies are supported. Surge protection is 6 kV, ESD ±4 kV contact and ±8 kV air. Metal case 102.9 x 48.9 x 27.0 mm, 0.2 kg, wall mounted or on an optional DIN rail, operating range -20 °C to 60 °C, humidity 5 to 95 % non-condensing, EN62368-1, MTBF above 50,000 hours.
Not in stock · delivery 2-3 weeks
Indoor PoE++ injector to IEEE 802.3bt, backward compatible with 802.3at and 802.3af. It supplies one Gigabit port with up to 90 W across four pairs at 54 V DC, pinned 1/2 (-) with 3/6 (+), then 4/5 (+) with 7/8 (-), over a cable run of 100 m. It suits loads that draw heavily, such as speed domes or housings with heater, blower, wiper and illuminator. Terminals outside the standard are detected and protected. Mains input 100–240 V AC, rated to 280 V AC for four hours and 300 V AC for one minute. Surge protection: 6 kV at the data and PoE port, 4 kV at the mains input. Case 182 x 78.6 x 41.9 mm, 0.58 kg, -10 °C to 50 °C, humidity 10–90 % non-condensing.
Not in stock · delivery 2-3 weeks
Mid-span injector for a single Gigabit run indoors. It puts power onto an existing 10/100/1000Base-T line and so feeds devices a plain switch port cannot: speed domes, or camera housings carrying a blower, heater, illuminator and wiper. Power leaves as 95 W PoH on all four pairs at 54 V DC, pinned 1/2 (-) with 3/6 (+), then 4/5 (+) with 7/8 (-), and reaches 100 m. It works with IEEE 802.3at/af and recognises non-standard terminals, protecting them. Input 100–240 V AC, briefly 280 V AC for four hours and 300 V AC for one minute. Surge protection is 6 kV at the data/PoE port and 4 kV on the mains side. 182 x 78.6 x 41.9 mm, 0.58 kg, LEDs for power and PoE, -10 °C to 50 °C.
Not in stock · delivery 2-3 weeks
The 2E11-110-RX-V2 is the receiving half of an EPo2 pair: it takes data and power off the two-wire run and presents them at a 10/100 Mbit/s RJ45 port as a powered device. It can be fed from the two-wire line itself or from 48 to 56 V DC, and passes PoE through to the connected device. IP equipment can therefore reach the network where only old two-conductor wiring exists. No configuration is required and the unit itself draws 2 W.
Not in stock · delivery 2-3 weeks
EPoC receive adapter carrying one 75 Ω BNC port and one 10/100 Mbps PoE PD port, placed at the head end of a coaxial run. All power for the link is sourced from a PoE switch or injector: it accepts IEEE 802.3bt at 90 W, 802.3at at 30 W and 802.3af at 15.4 W as end-span or mid-span, or 48 to 56 VDC, and the manufacturer recommends 802.3bt with 90 W for long runs. Over RG59, RG6 or RG11 it passes data and PoE to the TX adapter and the camera as far as 1,200 m at 100 Mbps, with data alone reaching 2,400 m, so older CCTV cabling can move to IP without new cable. The unit draws 2 W. An eight-bay 19-inch chassis (CH-110-V2) and the SD-301 surge protector are optional. Metal case 103.4 x 48.9 x 27 mm, 0.2 kg, wall or optional DIN-rail mounting, operating range -20 °C to 60 °C, EN62368-1.
Not in stock · delivery 2-3 weeks
Receive end of an EPoT link, sitting at the head of the run: one EPoT port on RJ45 and one 10/100 Mbps PoE PD port. Every watt for the link is drawn from a PoE switch or injector – IEEE 802.3bt at 90 W is the recommendation – and 30 W, 60 W or 48 to 56 VDC at the DC jack are accepted as well. Data and power travel over shielded Cat5e/6 STP/FTP cable on four pairs, two pairs or one pair for as far as 1,200 m, with data alone reaching 2,400 m at 100 Mbps. That feeds both the TX adapter and the camera at the far end with no switch or power supply in between. Peer-to-peer, daisy-chain and failover ring topologies work, and an eight-bay 19-inch chassis (CH-110-V2) is available as an option. The unit draws 2 W; surge protection is 6 kV, ESD ±4 kV contact and ±8 kV air. Metal case 102.9 x 48.9 x 27.0 mm, 0.2 kg, wall or optional DIN-rail mounting, operating range -20 °C to 60 °C, EN62368-1.
Not in stock · delivery 2-3 weeks
10G SFP,SMF Bi-Di, TX:1270NM / RX:1330NM,40KM
Not in stock · delivery 2-3 weeks
10G SFP,SMF Bi-Di, TX:1270NM / RX:1330NM,20KM
Not in stock · delivery 2-3 weeks
10G SFP,SMF Bi-Di, TX:1330NM / RX:1270NM,20KM
Not in stock · delivery 2-3 weeks
10G SFP,SMF Bi-Di, TX:1330NM / RX:1270NM,40KM
Not in stock · delivery 2-3 weeks
SFP+ module with an RJ45 socket that puts a 10 Gbps slot onto copper: 10GBASE-T to IEEE 802.3an with a 30 m reach over Cat.6a. Auto-negotiation and auto-MDI/MDI-X are supported and the module draws 3.3 V. Operating range 0 °C to 70 °C, storage -40 °C to 85 °C, humidity 5 to 90 % non-condensing. Body size 68.3 x 13.7 x 13.8 mm, MSA compliant.
Not in stock · delivery 2-3 weeks
SFP+ module for 10 Gbps on 9/125 μm single-mode fibre with a 10 km reach, typically an uplink between buildings on one site. The FP laser diode works at 1310 nm and transmits at -8.2 to 0.5 dBm, the receiver from -14.4 dBm downward, and the link budget is 6.2 to 14.9 dB. LC connector, 3.3 V supply, operating range 0 °C to 70 °C, storage -40 °C to 85 °C, humidity 5 to 90 % non-condensing. Size 68 x 13.7 x 8.5 mm, MSA compliant, approvals CE, FCC, LVD, ROHS, TUV and UL.
Not in stock · delivery 2-3 weeks
SFP+ module carrying 10 Gbps over single-mode spans of up to 40 km on 9/125 μm fibre. Its DFB laser diode works at 1550 nm and transmits at -3 to 3 dBm; the receiver needs no more than -15.8 dBm, and the permitted link budget runs 12.8 to 18.8 dB. Connector LC, supply voltage 3.3 V. Operating range 0 °C to 70 °C, storage -40 °C to 85 °C, humidity 5 to 90 % non-condensing. Size 68 x 13.7 x 8.5 mm, MSA compliant, approvals CE, FCC, LVD, ROHS, TUV and UL.
Not in stock · delivery 2-3 weeks